Crest Electronics CDVS-7000 Manuale Utente Pagina 317

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 341
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 316
User Manual
i Series / iX Series 303
9.9.10 Appendix 1: ABD Switching Transients Test Window
Figure 9-69: ABD0100.1.8 Switching Transient Control Window
The ABD0100.1.8 Switching Transients screen provides a high level of control for performing AC
or DC transient tests according to appendix 1 of the ABD0100.1.8. The switching transient tests
are also incorporated in the ABD Table test screen but the parameters for these tests are pre-set
by the test sequence files provided. Using the ABD0100.1.8 Switching Transient control window,
transient parameters can be set interactively and resulting transient timing is displayed
graphically.
Both Figure A (Transparency Tests) and Figure B type transients (Transient Tests) can be
selected and parameter permutations for Figure B tests are automatically generated and
displayed in the transient permutations table above the time domain display.
Vedere la pagina 316
1 2 ... 312 313 314 315 316 317 318 319 320 321 322 ... 340 341

Commenti su questo manuale

Nessun commento